82
Issued: 28.02.2005
Strider MD 4 Plus
70 A fuse = strip fuse -
Fuse holder at the plus pole
of the batteries (illustration
without insulating cap)
To replace Fuse:
Remove insulating cap of the fuse
holder.
Loosen both clamping screws
(1, SW 4 mm) of the strip fuse.
Replace fuse strips (2) and tighten
claming screws.
Place insulating cap of fuse holder.
Repairs - fuses
2 types of battery fuses are used.
Type 1:
70 A fuse = strip fuse -
Fuse holder in the plus pole
cable of the batteries
To replace Fuse:
Unscrew fuse housing.
Pull out fuse holder.
Loosen both clamping screws
(1, SW 4 mm) of the strip fuse.
Replace fuse strips (2) and tighten
clamping screws.
Screw together fuse housing.
Battery fuse: type 2
Battery fuse: type 1
Type 2:
Fire and burn hazard by
bridging the Battery Poles!
Do remove insulator of fuse holder only.
17.5.2 Battery Fuses